t46-mode-layer-plan.log 3.2 KB

1234567891011121314151617181920212223242526272829303132
  1. PASS A1-overview-shows-everything — 总览 monitoring-point|MP-A monitoring-point|MP-B unassociated-equipment|EQ-FREE-1
  2. PASS A2-infrastructure-hides-monitoring — 基础设施 0 个标记(监测点/未关联设备/关联设备全隐藏)
  3. PASS A3-monitoring-shows-points — 运行监测 monitoring-point|MP-A monitoring-point|MP-B unassociated-equipment|EQ-FREE-1
  4. PASS A4-warning-only-abnormal-points — 预警处置 monitoring-point|MP-A unassociated-equipment|EQ-FREE-1(正常点 MP-B 不在、异常未关联设备在)
  5. PASS A5-associated-device-matrix — 关联设备各模式 2/0/2/1
  6. PASS A6-work-order-offline-not-abnormal — 工单/离线不构成异常点(标记 0 个)
  7. PASS A7-abnormal-data-missing-degrades-honestly — 异常数据未就绪:标记 0 个,降级说明 abnormal-devices-unready,pipelines-unready
  8. PASS A8-pipeline-resident-in-all-modes — 管线在四模式均为可见层(契约就绪=ready;未就绪应是 degraded 而非 hidden)
  9. PASS A8b-pipeline-unready-still-visible-not-hidden — 管线数据未就绪四模式都是 degraded(degraded ≠ hidden:不把缺数据伪装成"该模式没有")
  10. PASS A9-facility-only-overview-infrastructure — 设施点只在概览/基础设施可见,运行监测/预警处置隐藏
  11. PASS B1-intro-plan-empty — 引导态全空(markers 0 / legend 0 / targets 0)
  12. PASS C1-legend-matches-markers-overview — 图例与标记逐键一致
  13. PASS C1-legend-matches-markers-infrastructure — 图例与标记逐键一致
  14. PASS C1-legend-matches-markers-monitoring — 图例与标记逐键一致
  15. PASS C1-legend-matches-markers-warningResponse — 图例与标记逐键一致
  16. PASS D1-locate-targets-follow-mode — 预警处置回联目标 MP-A/EQ-FREE-1
  17. PASS D2-infrastructure-has-no-monitoring-targets — 基础设施模式下没有监测点回联目标(不拿监测点坐标冒充设施)
  18. PASS E1-ready-layers-no-note — 设施/管线契约就绪(空数组也是就绪)时无降级说明
  19. PASS E2-unready-layers-degraded-notes — 未就绪说明 facilities-unready,pipelines-unready
  20. PASS F1-preserve-suspends-in-infrastructure — 选 MP-B:基础设施暂停(visible=false)、切回总览恢复(visible=true)
  21. PASS F2-submode-switch-clears-selection — 分项↔分项清空选择
  22. PASS F3-overview-submode-preserves — 总览↔分项保留选择身份
  23. PASS F4-device-selection-pauses-by-mode — NORMAL 设备选中在预警处置暂停(false)、ALARM 设备可见(true)
  24. PASS F5-free-equipment-selection — 未关联设备在基础设施暂停(false)、预警处置可见(true)
  25. PASS F6-no-location-device-detail-visible — 不上图设备(no-location)的设备级详情可见(visible=true)—— 详情与能否上图无关
  26. PASS G1-infrastructure-hides-all-associated — 基础设施对任何设备状态都隐藏
  27. PASS G2-warning-only-attention-statuses — 预警处置只认设备自身 ALARM/WARNING(未知不猜)
  28. PASS G3-overview-monitoring-show-all — 概览/运行监测显示全部(状态未知也显示,不凭状态隐藏)
  29. PASS G4-attention-predicate-consistent — 「需要处置」两态判据一致
  30. T46 模式图层计划检查:29/29 项通过。
  31. T46 模式图层计划全部通过。